وقتی کولر گازی در حالت سرد نکردن کار می کنه چراغ  سبز چشمک می زنه و رونه کاری به حالت زیر کار می کند

  During heating mode, the temperature of room and evaporator is low, to avoid cold air blowing, the indoor unit runs in anti-cold air mode. when the evaporator temperature is below 15, the indoor motor doesn’t run, the outdoor unit runs. When the evaporator temperature is between 15 and 30, the indoor motor runs in breeze(lower than low speed),

On anti-cold mode, outdoor unit keep running, so evaporator temperature rise rapidly. When the evaporator temperature rise to 26, the indoor motor runs in breeze, when rise to 30, the indoor motor runs in low speed, when rise to 34, the motor runs in midium speed, when the evaporator temperature is increased to 38,the indoor motor runs in the set speed.

`